ESC Medicams 400W Bipolar Electrosurgical Cautery Machine

₹53,550.00

This 400 W Microprocessor-Controlled Electrosurgical Unit is a versatile high-power generator. It is engineered for efficient tissue cutting, coagulation, and hemostasis across diverse surgical disciplines. It integrates both monopolar and bipolar modalities.…

Description

This 400 W Microprocessor-Controlled Electrosurgical Unit is a versatile high-power generator. It is engineered for efficient tissue cutting, coagulation, and hemostasis across diverse surgical disciplines. It integrates both monopolar and bipolar modalities. It has an automated safety lockout that completely halts monopolar activity when the bipolar mode is active to prevent accidental burns. It delivers precise energy control with minimal RF distortion. It ensures optimized clinical outcomes by minimizing blood loss and peripheral tissue damage. It supports advanced patient safety with comprehensive isolation and connection monitoring systems.
Key Features:
Separate Modality Operations: Isolates monopolar and bipolar functions with individual footswitches. Activating the bipolar mode automatically disables all monopolar handswitch and footswitch activities to prevent unintended thermal injuries.Tissue-Protective Bipolar Coagulation: Delivers targeted bipolar coagulation that prevents tissue charring, adhesion, and the blanching of adjacent healthy tissues.Enhanced Cut & Coag Flexibility: Provides a multi-mode configuration including specialized Blend options for adjustable hemostasis and an Endo Cut mode for flexible control during delicate procedures.Advanced Patient Safety: Features a body-protected and cardiac-protected design, a Patient Plate Fault Monitoring system, and explicit audible and visual indicators for both electrode connections and insulation monitoring.Dual Interface Control: Supports both standard handswitch and footswitch operation with user-settable program modes for custom procedural setups.Wide Clinical Versatility: Designed to fulfill the energy demands of general surgery as well as highly specialized procedures including neurosurgery, orthopedics, and ENT.Technical Specifications:
Control Architecture: Microprocessor-controlled electrosurgical unitHigh Frequency Power Output: 400 Watts maximumSignal Performance: Minimum RF distortionHF Leakage Current: > 150mAUser Settings: Programmable, user-settable program modesSafety Isolation: Body-protected and cardiac-protected circuitryPhysical Dimensions: 410 mm (L) x 355 mm (W) x 155 mm (H)Weight: Approximately 7.5 KgMode Configurations:CUT (4 Modes): Pure Cut, Blend 1, Blend 2, Endocut (Pure cut is supplemented by Blend 1 and Blend 2 to offer varying degrees of intraoperative hemostasis).COAG (4 Modes): Spray, Force, Fulgurate, DesiccateBIPOLAR (4 Modes): Micro, Macro, Cut, Auto-ModeFAQs:
How does the system mitigate the risk of accidental surgical burns when switching modalities?The generator features an automatic safety lockout system. The moment the generator is transitioned into its bipolar mode, all monopolar activations via both the handswitch and footswitch are completely stopped, preventing uncalled burns.What are the clinical benefits of the specialized bipolar function on this unit?The bipolar feature is specifically tuned to provide effective coagulation without causing tissue charring, adhesion to the instrument, or the blanching of adjacent peripheral tissues.

Additional information

Brand

ESC Medicams

Model

400W

Condition

Brand New

Weight

7.5