Description
The Auto Photo Colorimeters that are offered have the ability to auto zero and are available in both absorbance and percent T modes. These are compact in design and include an integrated rechargeable battery supply that can be used for both mains and backup power. They offer accurate and stable performance. These come in the LT-114 (Digital) variant, which has a standard glass filter, a 1 ml small volume, a 3 digit, brilliant red 7 segment LED display, a working range of 400-700 nm, an output OD of 0 to 1.99, and a %T of 0 to 199. In addition, the system has a 0.5% FSI accuracy and supports both photodiode and selenium photocell detectors for effective operation.
Features of Labtronic LT114 Auto Photo Colorimeter:
Output (OD): Ranges from 0 to 1.99. OD stands for Optical Density, a measure of absorbance of light by a substance. This indicates the intensity of light absorbed by a sample, often used in spectrophotometry.Transmittance (%T): Ranges from 0 to 199. %T represents the percentage of light transmitted through a sample. It is complementary to OD, with higher %T indicating less absorption.Power: Operates at 230V AC with a tolerance of +10%. Frequency is 50 Hz. AC. This specifies the electrical requirements for the device.Accuracy: The accuracy is specified as 0.5% Full Scale Input (FSI). This indicates the precision of measurements relative to the full scale of the instrument. Detector: Utilizes either a Selenium Photocell or a Photodiode. These are types of photodetectors that convert light into an electrical signal.Display: Features a 3-digit display with bright red 7-segment LED. This provides a visual representation of the measured values.Light Source: Requires a 6.8V, 300mA power source. This is the illumination source used for measuring absorbance or transmittance.Minimum Volume: The minimum sample volume required for measurement is 1 ml.Resolution: The resolution for OD measurements is 0.01, and for %T measurements, it is 1%. This indicates the smallest incremental change that can be detected by the instrument.Standard Glass Filters: Comes with 8 standard glass filters. These filters are likely used for calibrating the instrument or for specific wavelength measurements.Wavelength Range: The device can measure wavelengths within the range of 400 to 700 nm. This specifies the spectrum of light that the instrument is capable of detecting.Specifications of Labtronic LT-114 Auto Photo Colorimeter:
Product NameLabtronic LT114 Auto Photo ColorimeterBrandLabtronicModelLT114 Output0 to 199Accuracy0.5% FSIDetectorSelenium Photocell/PhotodiodeDisplay3 Digit, Bright Red 7 Segment LEDLight Source6.8v, 300mAMinimum Volume1 mlResolution0.01, %T : 1%Std Glass Filters8 FiltersWavelength Range400-700 nmPower230V + 10%, 50 Hz. AC






Reviews
There are no reviews yet.